Should Labs impose Desperation Premiums?

Every so often it's useful to transpose a few practices from outside the laboratory into the laboratory, just to see how we would evaluate them. The new Tech powers are gleefully implementing a system called "surveillance pricing", which they sell as a dynamic way to sell things to customers, except it turns out that they really only want the prici...

Continue reading
  433 Hits

Indonesian hematology analyzer that can't hit anything

A paper from Surabaya, Indonesia assessed the performance of an anonymous hematology analyzer. The study used the old CLIA 1992 goals. We updated it with an assessment using CLIA 2025 goals. And then it became clear why this instrument was not named. None of this performance would meet CLIA's standards. Is performance so bad in this analyzer, ...

Continue reading
  728 Hits

Question and Answer: How to use the 7:T rule?

This question recently came in: "We have two specific questions regarding the practical application of the 7T rule: "When applying this rule, is it mandatory to use the 1:2s rule as a starting trigger, or can the laboratory choose to use 7T independently without the 1:2s initiation? (Personally, I believe 1:2s initiation is necessary….) "When a 7T ...

Continue reading
  616 Hits

4:1s, when is it violated under different types of Westgard Rules?

The Westgard Rules, in the classic 1981 multirule paper, require a 1:2s violation before other rejection rules are violated.  If you had4 values past 1s, but nothing past 2s, it wouldn't be checked. Under more "modern" Westgard Rules, with the 1:2s warning rule abolished, you don't need to wait until the 2s limit line is violated before interp...

Continue reading
  747 Hits

Repeating the control: just more info, or just rolling the dice?

A recent question popped up in one of our recent webinars: "It seems to me that repeating a QC may or may not have value, yes if it provides further troubleshooting data, and not if it is used to override a proper error flag. But to group the two together, without making that distinction seems inappropriate. Perhaps expand the survey ques...

Continue reading
  809 Hits

Q and A: Is the 10:x rule still compulsory?

A recent question came to me via social media: "Hello Sir, Good morning, How are you? I wanted to know is still 10x rule is coumpulsary?[stet.]  Even [when] we are using lab mean and lab SD. Please share the details.Thanks and Regards, [anonymous]"10:x is not compulsory by any regulation that I am aware of. Many regulations require you to...

Continue reading
  955 Hits

"Real" analytical Sigma metrics, a rarity

[Full disclosure, Westgard QC has a partnership with Beckman Coulter. However, this paper was not prepared by Westgard, but was written completely independently. We are simply calling attention to the study's unique approach and findings.] A new study from Tamil Nadu, India, has gone into unprecedented detail of the analytical performance. Typicall...

Continue reading
  1113 Hits

CGM quality, compromised?

A significant new paper just became available online, tackling the difficult challenge of CGM quality: Clinical assessment and acceptance criteria for continuous glucose monitoring (CGM) system performance: A proposed guideline by the IFCC Working Group on CGM, Pleus S, Eichenlaub M, Dabla PK, Diem P, Boija EE, Fokkert M, Hinzmann R, Jendle J, Klon...

Continue reading
  1951 Hits

What Six Sigma Feels like... (and 2,3,4, and 5 too)

Interesting study published recently in the October 2025 issue of Philippine Journal of Pathology: Mark Angelo Ang, Karen Cybelle Sotalbo, Quantifying Total Allowable Error Violations in Serum-Sodium Quality Control: A Computer Simulation Experiment of Two- to Six-Sigma Processes, October 2025, Philippine Journal of Pathology 10(2), DOI: 10.21141/P...

Continue reading
  1839 Hits

Are labs getting ensh***fied?

The term "enshittification" is having a moment right now. It was coined in 2022 by the author/essayist Cory Doctorow, and named the 2023 and 2024 word of the year by the American Dialect Society  and the Macquarie Dictionary, but the publication of the eponymous book is bringing it to the fore. Enshittification is a on...

Continue reading
  1470 Hits

198 Questions: Where do I start with Six Sigma?

We're still working through questions that came up in our Global QC Survey results webinar. Question: What's your advice to labs new to Sigma metrics? How to gradually transition? We're at an interesting time in the evolution of analytical Six Sigma metrics. Many of the major control vendors have built analytical Sigma metric calculations righ...

Continue reading
  1302 Hits

199 Questions: What can poor labs do?

199 questions from the Beckman Coulter Webinar. Another common inquiry I have gotten over the last few months concerns the advanced technique of Six Sigma and its applicability in not-so-advanced laboratories. In other words, what can resource-challenged laboratories do with Six Sigma metrics? This question applies not only to hematology, but to an...

Continue reading
  1687 Hits

A new game: 200 questions?

Driving Quality in Hematology: New Global Standards, Interlaboratory Data, and Real-World Sigma Metric Success | Beckman Coulter DX HGM .... https://app.livestorm.co/beckman-coulter-dx-hgm/driving-quality-in-hematology-new-global-standards-interlaboratory-data-and-real-world-sigma-metric-success?s=0b6c18b1-6f1e-4c6f-90ee-48cf88783f8d We had more th...

Continue reading
  2259 Hits

#CLINICAL24 celebrates the lab

Happy to be part of the #CLINICAL24 celebration of laboratory professionals and laboratory medicine again this year. My own small contribution to this global conversation can be found here: https://www.selectscience.net/video/maintaining-qc-accuracy-in-clinical-labs-through-responsible-ai-use #clinical24 #westgardrules #westgardsurveys

Continue reading
  947 Hits

European QC habits: more QC, more problems

Where do labs run more QC more often than anywhere else?https://westgard.com/qc-applications/basic-qc-practices/2025-qc-survey-europe.html See the latest findings from the Westgard Global QC Survey.Sometimes more QC just means more (self-inflicted) problems. #westgardrules And if you don't want to glance through hundreds of graphs, you can get the ...

Continue reading
  1033 Hits