Grids - Westgard QC - Blog - Page 34 - Results from #330

Tools, Technologies and Training for Healthcare Laboratories

Q & A on ISO and QC: Are Mean Rules Mandatory?
Sten Westgard
ISO
Posted by Sten Westgard, MS Recently, a user submitted a question about the mandatory use of the 10x rule on chemistry analytes as mandated by ISO 15189 through NABL: "Specific criteria of accreditation of NABL India (for ISO 15189) say that 10x should be considered as a violation for clinical chemistry  and Immunoassay parameters. However we understand that Westgard rules consider it as a warning only. Please advise." So, the central question is, does ISO 15189 mandate the use of the 10x control rule? -----
Quality Indicators can be dangerous to your health
Sten Westgard
Journal Watch
-----
Pop Quiz: What does healthcare think of Risk Analysis?
Sten Westgard
Current Affairs
Posted by Sten Westgard, MS So we all know that Risk Analysis is coming to laboratories in the US. (click here if this is news to you). But Risk Analysis, particularly the FMEA technique (Failure Mode and Effects Analysis), is not new to healthcare. Outside the laboratory, plenty of healthcare practitioners have been performing FMEA. So what do they think about this technique? Try and guess which one of these responses is from a someone in healthcare: "The jury's still out on the FMEA process because... has anybody evaluated FMEA as a tool for analysing risk? And it turns out there isn't... well why are we doing this process?... When all it is doing is bringing a few things to the surface, which is no bad thing, but it's not a validated process." "...Forget FMEA. It doesn't really work effectively, I don't think, and the scores are a hindrance rather than anything else, year... We wasted a lot of time on FMEA before we realized, this isn't actually working. Yeah, because I think you can get caught up on just the score, that's the thing." "The scoring in the FMEA teams need to be the same people, if you change half way through because of the highly subjective interpretation things change dramatically." -----
What's New on Westgard Web: January 2012
Sten Westgard
What's New on Westgard Web
Posted by Sten Westgard, MS
More Error Rates at POC
Sten Westgard
Error rates
Posted by Sten Westgard, MS In the December 2011 issue of Point of Care journal, an interesting study was published: Preanalytical Errors in Point-of-Care Testing: Auditing Error of Patient Identification in the Use of Blood Gas Analyzers, Natalie A Smith, David G Housley, Danielle B. Freedman, Point of Care, Volume 10: Number 4, December 2011. The study looked at patient identification errors on a blood gas analyzer in various departments in a hospital. Bearing in mind that this is just one type of pre-analytical error, what do you think the rate was? Given around 100,000 tests, what would you guess as the number of defects? -----
What Traceability and Sigma-metrics share in common: A Need for Good Data
Sten Westgard
Journal Watch
Posted by Sten Westgard, MS
What's New on Westgard Web: December 2011
Sten Westgard
What's New on Westgard Web
Posted by Sten Westgard, MS
An Advisory on Blood Glucose Meters
Sten Westgard
Current Affairs
Posted by Sten Westgard, MS [Hat-tip to the AACC Point-of-Care listserve, which first posted a notice about this article] The Pennsylvania Patient Safety Advisory has a regular electronic newsletter highlighting new science and studies about healthcare safety. Their December 2011 issue has a particularly interesting article for laboratory testing: Point-of-Care Technology: Glucose Meter's Role in Patient Care, Lea Anne Gardner, PhD, RN, Senior Patient Safety Analyst, Pennsylvania Patient Safety Authority. This review examined more than 1,300 reports of glucose-meter problems from the Pennsyvlania reporting system database from 2004 to 2011. Of those reports, 71 near-miss or adverse event reports occurred. Most intriguing are the report excerpts directly quoted in the study. Of those reports, 72% of the near-miss or adverse events occurred with high-blood glucose results. That is, where the glucose meter had a sudden high value that may or may not have been reflective of the actual patient's clinical state. For example: "A patient's blood sugar was checked using a [glucose meter]. The lunchtime result was 517. A [blood glucose test] was [immediately] retaken to check for accuracy, and the result was greater than 600. A blood [laboratory] test was conducted per protocol, and the [lab] glucose [result] was 136..." What do you think happened next? -----
Six Sigma in the Lab literature
Sten Westgard
Journal Watch
Posted by Sten Westgard, MS
Nine Questions about Risk-Based QC Plans
Sten Westgard
CLIA
Posted by Sten Westgard, MS Now that we know EQC will officially be phased out and instead Labs will have to develop QC Plans through Risk Analysis (as explained in CLSI's new guideline EP23A), some of the waiting is over. EQC, which was fatally flawed from the start, is going to go away. However, the exact regulations about QC Plans and Risk Analysis have yet to be written (or, at least, are not yet known by the general public). What makes this more uncertain is that EP23A is only meant as a guideline, and the Risk Analysis approach discussed in the guideline is only meant as a possible example. Risk Analysis is a long-established technique (outside the medical laboratory) and has many different formats and levels of complexity. Even between EP18 and EP23, there are discrepancies between the Risk Analysis recommendations (EP18 recommends a 4-category ranking of risk, while EP23 recommends a 5-category approach). So while we're waiting for the other shoe to drop (in the form of detailed regulations and accreditation guidelines governing Risk Analysis), we might as well talk about what questions those rules will have to answer... -----